1. Check the tension of the generator drive belt by pressing it with your finger between the generator and crankshaft pulleys. When pressed with a force of 100 N (10 kgf), the belt deflection should be 8–12 mm.
Note: To check the tension, you can use a spring balance scale by pulling the belt branch with a hook.

2. To adjust the belt tension, loosen the nut securing the generator to the tension bracket.

3. Adjust the belt tension with the adjusting bolt.