Table 14.2.1. Battery technical data
Name | Values |
Model | 6ST 62VL |
Type | Unattended |
Polarity | Reverse |
Rated voltage, V | 12 |
Rated capacity, Ah | 62 |
Battery charge current, A | 6 |
Cold crank current (according to EN standard), A | 600 |
Weight, not more than kg | 16,5 |
Table 14.2.2. Electrolyte density depending on the degree of contamination of the battery and climatic conditions
Climatic operating conditions | Electrolyte density (at +25°C), g/cm3 | |||
poured into the battery when refueling | in a battery in which the state of charge of the batteries | |||
100% | 75% | 50% | ||
Hot climate (all year round) | 1,23 | 1,25 | 1,21 | 1,17 |
Temperate climate (all year round) | 1,25 | 1,27 | 1,23 | 1,19 |
cold climate (all year round) | 1,26 | 1,28 | 1,24 | 1,20 |
Very cold: in winter | 1,28 | 1,30 | 1,26 | 1,22 |
in summer | 1,26 | 1,28 | 1,24 | 1,20 |
Table 14.2.3. The degree of charge of the battery depending on the voltage at its terminals
Voltage at battery terminals, V | Degree of charge, % |
12,6 | 100 |
12,4 | 75 |
12,2 | 50 |
12,0 | 25 |