Removing
Place the car on the workplace, brake with the parking brake, turn off the ignition. Raise the hood, disconnect the wire terminal "masses" from battery (wrench "on 10").
Figure 13-1 - Storage box: 1 - glove box; 2 - ceiling light for the glove box; 3 - diagnostic block
Figure 13-2 - Glove box lamp housing: 1 - latch; 2 - block wiring harness of the instrument panel
Disengage retainer 1, Figure 13-2, and remove dome light 2, Figure 13-1, glove box lighting 1 (flat screwdriver).
Disconnect connector 2, Figure 13-2, instrument panel wiring harness from glove box light.
To replace the glove box dome light bulb, remove it and replace the burnt out bulb.
Note: Use only a certified C5W lamp for replacement.
Installation
Install the bulb and the glove box light in the reverse order of removal.